3.2. Remote control commands
785 DMP Titrino
80
*Parameter Tree part "Parameters for MET"
├ .TitrPara Titration parameters
│ ├ .VStep Volume increment 0...0.10...999.9 3.2.2.12.
│ ├ .DosRate Dispensing rate for increments 0.01...150.0, max. 3.2.2.13.
│ ├ .SignalDrift Drift for meas. value acquisition depends on meas.quant. 3.2.2.14.
│ ├ .UnitSigDrift Unit of measured value drift read only ditto
│ ├ .EquTime Equilibrium time 0...26...9999, OFF ditto
│ ├ .StartV Start volume
│ │ ├ .Type Type of start volume abs., rel., OFF 3.2.2.15.
│ │ ├ .V Volume for absolute start volume 0...999.99 ditto
│ │ ├ .Factor Factor for relative start volume 0...±999 999 ditto
│ │ ├ .Rate Dispensing rate for start volume 0.01...150.0, max. ditto
│ ├ .Pause Waiting time 0...999 999 3.2.2.1.
│ ├ .MeasInput Measuring input 1, 2, diff. 3.2.2.18.
│ ├ .Ipol Polarization current 0...1...±127 ditto
│ ├ .Upol Polarization voltage 0...400...±1270 ditto
│ ├ .PolElectrTest Test for polarized electrodes ON, OFF ditto
│ ├ .Temp Titration temperature -170.0...25.0...500.0 3.2.2.19.
│
├
.StopCond Stop conditions
│ ├ .VStop Stop volume
│ │ ├ .Type Type of stop volume abs., rel., OFF 3.2.2.20.
│ │ ├ .V Volume for absolute stop volume 0...99.99...9999.99 ditto
│ │ ├ .Factor Factor for relative stop volume 0...±999 999 ditto
│ ├ .MeasStop Stop measured value pH, U, I depends on meas.quant. 3.2.2.21.
│ ├ .UnitMStop Unit of stop measured value read only ditto
│ ├ .EPStop Stop after a number of EP's 1...9, OFF 3.2.2.22.
│ ├ .FillRate Filling rate 0.01...150.0, max. 3.2.2.23.
│
├
.Statistics Statistics
│ ├ .Status Status of statistics calculation ON, OFF 3.2.2.24.
│ ├ .MeanN No. of individual determinations 2...20 ditto
│ ├ .ResTab Result table
│ │ ├ .Select original,delete n,delete all ditto
│ │ ├ .DelN Deletion of individual results 1...20 ditto
│
├
.Evaluation Evaluation
│ ├ .EPC EP criterion depends on meas.quant. 3.2.2.25.
│ ├ .Recognition EP recognition
│ │ ├ .Select Type of EP recognition all,greatest,last,window,OFF ditto
│ │ ├ .Window Window
│ │ │ ├ .1 up to 9 windows
│ │ │ │ ├.LowLim Lower limit window 1 depends on meas.quant. ditto
│ │ │ │ ├.UpLim Upper limit window 1 depends on meas.quant. ditto
│ ├ .FixEP Fix endpoints
│ │ ├ .1 up to 9 fix EP's
│ │ │ ├.Value Measured value for fix EP1 depends on meas.quant. ditto
│ ├ .pK pK or HNP evaluation ON, OFF ditto
│
├
.Presel Preselections
│ ├ .IReq Request of Id's after start id1, id1&2, all, OFF 3.2.2.26.
│ ├ .SReq Request of sample size after start value, unit, all, OFF ditto
│ ├ .LimSmplSize Limits for sample size 3.2.2.27
│ │ ├ .Status Status of limit control ON, OFF ditto
│ │ ├ .LoLim Lower limit 0.0...999 999 ditto
│ │ ├ .UpLim Upper limit 0.0...999 999 ditto
│ ├ .ActPulse Output of a pulse ON, OFF 3.2.2.28.