2.2 Modes
765 Dosimat
9
2.2.2 Mode DIS R, Repetitive Dispensing
Dosimat is dosing a stored dispensing volume if <GO> is pressed. The burette cylinder
is refilled and display reset to 0.000 mL.
V-DIS 1. ml
Dispensing volume
Input range: 0.001...999.999 mL
Expelling and filling rate, see page 6.
2.2.3 Mode DIS C, Cumulative Dispensing
Dosimat is dosing a stored dispensing volume if <GO> is pressed, and the dispensed
volume (V–DIS) remains displayed.
V-DIS 0.1 ml
V-LIM OFF ml
Dispensing volume
Input range: 0.001...999.999 mL
Security volume
Dispensing is stopped, if V-LIM has been reached.
Input range: 0.001...999.999 mL, OFF
Expelling and filling rate, see page 6.
Tandem Dosing
Mode DIS C is suitable for continuous dosing with 2 Dosimats, see page 57.