Metrohm TitrIC 4 User Manual

Browse online or download User Manual for Equipment Metrohm TitrIC 4. Metrohm TitrIC 4 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 16
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Application Bulletin 318 e
Installation Instructions of TitrIC 4
The TitrIC 4 System is used for the fully automatic analysis of water samples using direct measurement,
titration and ion chromatography. The following parameters are determined in a very short time:
temperature, conductivity, pH, acid capacity, calcium, magnesium, total hardness and, in parallel, the
concentrations of the individual anions. Further Metrohm instruments can be incorporated in the existing
system at any time and used to measure additional parameters.
Analytical sequence
1. Conductivity is measured in the sample vessel on the sample processor.
2. First sample transfer to the 881 Compact IC pro.
3. The IC anion determination is started automatically.
4. Second sample transfer to the external titration cell of the 815 Robotic USB Sample
Processor XL.
5. Temperature, pH and acid capacity (p and m values) calcium, magnesium and total hardness
are determined.
The whole procedure is controlled by the TitrIC software: The user enters the sample position and
sample identification, IC system and tiamo
TM
method, after which TitrIC transfers all the relevant
information to tiamo
TM
and MagIC Net. When the measurement has been concluded, TitrIC
automatically generates a joint report containing all results. This report can be printed out or exported
as an Excel file.
Page view 0
1 2 3 4 5 6 ... 15 16

Summary of Contents

Page 1 - Application Bulletin 318 e

Application Bulletin 318 e Installation Instructions of TitrIC 4 The TitrIC 4 System is used for the fully automatic analysis of water samples usi

Page 2 - Table of contents

Application Bulletin 318 e Installation Instructions of TitrIC 4 Page 10/16 5 Miscellaneous 5.1 Stirrer The 802 Rod Stirrer is inserted through openi

Page 3 - 1 Delivery package

Application Bulletin 318 e Installation Instructions of TitrIC 4 Page 11/16 6.2 Configuration of tiamoTM Æ The controller cable (6.2151.000), which is

Page 4 - Page 4/16

Application Bulletin 318 e Installation Instructions of TitrIC 4 Page 12/16 6.2.5 Solutions The solutions to be used must, as usual, be defined in tia

Page 5 - 2 Installation

Application Bulletin 318 e Installation Instructions of TitrIC 4 Page 13/16  TitrIC 4 - preparation of titration equipment: This method is used for

Page 6 - 3 Cable connections

Application Bulletin 318 e Installation Instructions of TitrIC 4 Page 14/16 Input window for the export template The entry Start counter is obtained

Page 7 - 4 Tubing connections

Application Bulletin 318 e Installation Instructions of TitrIC 4 Page 15/16 The target directory for the report is as following: Windows 2000, Window

Page 8 - 6.1805.030

Application Bulletin 318 e Installation Instructions of TitrIC 4 Page 16/16 6.4 Configuration of TitrIC Æ TitrIC is started (MagIC Net and tiamoTM are

Page 9 - Page 9/16

Application Bulletin 318 e Installation Instructions of TitrIC 4 Page 2/16 Table of contents 1 Delivery package...

Page 10 - 6 Software

Application Bulletin 318 e Installation Instructions of TitrIC 4 Page 3/16 1 Delivery package - delivered with TitrIC 4 package: Number Article

Page 11 - 6.2 Configuration of tiamo

Application Bulletin 318 e Installation Instructions of TitrIC 4 Page 4/16 - optional accessories: 1 6.2041.xxx Sample rack made of PVC 1 6.1432.x

Page 12 - 6.2.7 Methods

Application Bulletin 318 e Installation Instructions of TitrIC 4 Page 5/16 2 Installation The following is a detailed description of the TitrIC 4 Syst

Page 13 - Page 13/16

Application Bulletin 318 e Installation Instructions of TitrIC 4 Page 6/16 3 Cable connections First all the power cables are connected to the instrum

Page 14 - Page 14/16

Application Bulletin 318 e Installation Instructions of TitrIC 4 Page 7/16 4 Tubing connections 4.1 External cell The numbers given here (,…) and «

Page 15 - Page 15/16

Application Bulletin 318 e Installation Instructions of TitrIC 4 Page 8/16 4.2 Installation of the 50 mL Dosing Unit M6: Port 2 Luer: Port 46.5620.0

Page 16 - 6.4 Configuration of TitrIC

Application Bulletin 318 e Installation Instructions of TitrIC 4 Page 9/16 4.3 Overview of all the tubing connections The three 60-cm-FEP-tubing c

Comments to this Manuals

No comments